Tetpor Liquid (Membrane)
TETPOR LIQUID filters are particularly suitable for sterilisation and particulate removal from aggressive chemicals (including acids, bases, and solvents) within a wide range of critical processing industries. The superior performance, strength, and durability of TETPOR LIQUID filters stem from the use of a single layer, high-security PTFE membrane, which has a high dirt holding capacity due to its high voids volume. This results in low pressure drops and long service life.
High flow rates are achieved due to the optimised pleat pack density and the superior design construction of TETPOR LIQUID filters. TETPOR LIQUID filters may be repeatedly steam sterilised or autoclaved up to 142 °C (287.6 °F), providing the user with assured security of performance.
Technical Specifications
Materials of Construction
- Filtration Membrane: PTFE
- Upstream Support: Polypropylene
- Downstream Support: Polypropylene Filter Cartridges
- Inner Support Core: Polypropylene
- Outer Protection Cage: Polypropylene
- End Caps: Polypropylene
- End Caps Insert: 316L Stainless Steel
- Standard o-rings/gaskets: Viton
MURUS Disposable Filter Capsules
- Core: Polypropylene
- Sleeve: Polypropylene
- Standard o-rings/gaskets: Viton
- Capsule Body: Polypropylene
- Capsules Vent Seals: Silicone
DEMICAP Filter Capsules
- Core: Polypropylene
- Sleeve: Polypropylene
- End Caps: Polypropylene
- Capsule Body: Polypropylene
- Capsules Vent Seals: Silicone
- Filling Bell: Polycarbonate
Syringe Filters
- Body: Polypropylene
Recommended Operating Conditions
Filter Cartridges
- Up to 70 °C (158 °F) continuous operating temperature and higher short-term temperatures during CIP to the following limits:
MURUS Disposable Filter Capsules
- Up to 25 °C (77 °F) @ 5.5 barg (79.7 psig)
- Up to 60 °C (140 °F) @ 2.8 barg (40.6 psig)
Parker Hannifin certifies that this product complies with the European Council Pressure Equipment Directive (PED) 97/23/EC Article 3, Paragraph 3 – Sound Engineering Practice (SEP). This product is intended for use with Group 1 & 2 Dangerous and Harmless Liquids and Group 2 Harmless Gases at the operating conditions stated in this document. In compliance with PED Article 3, Paragraph 3, SEP, this product does not bear the CE mark.
DEMICAP Filter Capsules
- Up to 40 °C (104 °F) at line pressures up to 5.0 barg (72 psig)
Effective Filtration Area (EFA)
- 10” (250 mm): 0.77 m² (8.28 ft²)
- K Size: 0.36 m² (3.87 ft²)
- A Size: 0.25 m² (2.69 ft²)
- B Size: 0.12 m² (1.29 ft²)
- E Size: 0.06 m² (0.64 ft²)
- Syringe ø50 mm: 14.50 cm² (2.25 in²)
Sterilization
TETPOR LIQUID filter cartridges can be sanitized with hot water at up to 90 °C (194 °F) and are compatible with a wide range of chemicals. For detailed operational procedures and advice on cleaning and sterilization, please contact the Technical Support Group through your usual Parker domnick hunter contact.
Food and Biological Safety
Materials conform to the relevant requirements of 21CFR Part 177 and current USP Plastics Class VI – 121 °C and ISO10993 equivalents.
Quality Standards
Pharmaceutical grade products are manufactured in accordance with cGMP, 100% flushed with pharmaceutical purified water, and integrity tested prior to dispatch. A sample of each lot is tested to demonstrate conformity to validated claims.
Features and Benefits
- Superior chemical resistance of PTFE membrane combined with polypropylene hardware
- Integrity tested prior to dispatch
- Validated to ASTM F838-83 methodology
- Comprehensive range of end cap configurations for retrofitting