Skip to content

Technical Specifications

Materials of Construction

  • Filtration Membrane: PTFE
  • Upstream Support: Polypropylene
  • Downstream Support: Polypropylene Filter Cartridges
  • Inner Support Core: Polypropylene
  • Outer Protection Cage: Polypropylene
  • End Caps: Polypropylene
  • End Caps Insert: 316L Stainless Steel
  • Standard o-rings/gaskets: Viton

MURUS Disposable Filter Capsules

  • Core: Polypropylene
  • Sleeve: Polypropylene
  • Standard o-rings/gaskets: Viton
  • Capsule Body: Polypropylene
  • Capsules Vent Seals: Silicone

DEMICAP Filter Capsules

  • Core: Polypropylene
  • Sleeve: Polypropylene
  • End Caps: Polypropylene
  • Capsule Body: Polypropylene
  • Capsules Vent Seals: Silicone
  • Filling Bell: Polycarbonate

Syringe Filters

  • Body: Polypropylene

Recommended Operating Conditions

Filter Cartridges

  • Up to 70 °C (158 °F) continuous operating temperature and higher short-term temperatures during CIP to the following limits:

MURUS Disposable Filter Capsules

  • Up to 25 °C (77 °F) @ 5.5 barg (79.7 psig)
  • Up to 60 °C (140 °F) @ 2.8 barg (40.6 psig)

Parker Hannifin certifies that this product complies with the European Council Pressure Equipment Directive (PED) 97/23/EC Article 3, Paragraph 3 – Sound Engineering Practice (SEP). This product is intended for use with Group 1 & 2 Dangerous and Harmless Liquids and Group 2 Harmless Gases at the operating conditions stated in this document. In compliance with PED Article 3, Paragraph 3, SEP, this product does not bear the CE mark.

DEMICAP Filter Capsules

  • Up to 40 °C (104 °F) at line pressures up to 5.0 barg (72 psig)

Effective Filtration Area (EFA)

  • 10” (250 mm): 0.77 m² (8.28 ft²)
  • K Size: 0.36 m² (3.87 ft²)
  • A Size: 0.25 m² (2.69 ft²)
  • B Size: 0.12 m² (1.29 ft²)
  • E Size: 0.06 m² (0.64 ft²)
  • Syringe ø50 mm: 14.50 cm² (2.25 in²)

Sterilization

TETPOR LIQUID filter cartridges can be sanitized with hot water at up to 90 °C (194 °F) and are compatible with a wide range of chemicals. For detailed operational procedures and advice on cleaning and sterilization, please contact the Technical Support Group through your usual Parker domnick hunter contact.

Food and Biological Safety

Materials conform to the relevant requirements of 21CFR Part 177 and current USP Plastics Class VI – 121 °C and ISO10993 equivalents.

Quality Standards

Pharmaceutical grade products are manufactured in accordance with cGMP, 100% flushed with pharmaceutical purified water, and integrity tested prior to dispatch. A sample of each lot is tested to demonstrate conformity to validated claims.

Features and Benefits

  • Superior chemical resistance of PTFE membrane combined with polypropylene hardware
  • Integrity tested prior to dispatch
  • Validated to ASTM F838-83 methodology
  • Comprehensive range of end cap configurations for retrofitting

Related Products

SupaPore TL

SupaPore TL Microfiltration cartridges have been specifically designed for use in corrosive gas and liquid processing applications. A naturally highly hydrophobic PTFE membrane and Halar ECTFE structu...

SupaPore TP

SupaPore TP Microfiltration cartridges have been designed specifically for use in a wide range of aggressive gas and liquid processing applications. Its naturally hydrophobic PTFE membrane makes this ...

Bevpor PH

BEVPOR PH is an advanced membrane filter cartridge designed for the beverage industry to meet and surpass these criteria. Specifically developed as a beverage grade cartridge, BEVPOR PH utilizes an ad...

SupaPore NP

SupaPore NP Microfiltration cartridges use a pleated high surface area Nylon 66 membrane that has been designed for use in a wide range of liquid processing applications. The naturally hydrophilic Nyl...
Let’s talk

Our team is ready to discuss how we can find a performance solution for you.

Contact Us