Skip to content

Technical Specifications

Dimensions

  • Outside Diameter: 69mm
  • Typical Surface Area: 0.54 m² (Per 10”)

Sterilisation and Sanitisation*2

  • Steam or Autoclave: 121°C for 15 mins (40 cycles)
  • Hot Water: 90°C for 30 mins (0.2 bar ?p max)

*2 Applies to single open end cartridges only. For all steaming and hot water applications, the Reinforced Polypropylene End Cap option must be used.

Maximum Operating Conditions

  • Temperature: 80ºC
  • Recommended Maximum Differential Pressure:
    • Forward Flow: 4.0 Bar @ 20ºC
    • Reverse Flow: 3.5 Bar @ 20ºC
  • Recommended change-out differential pressure: 2.5 Bar

Materials of Construction

  • Filter Media: Halar (ECTFE)
  • Media Support: Polypropylene or Polyester
  • End Caps: Polypropylene
  • Cage/Core: Polypropylene

Product validation guide available on request. All SupaPore Halar cartridges are manufactured under strict control with batch number identification, giving full traceability on all components.

Features and Benefits

  • Broad chemical compatibility with a range of solvents and chemicals at an attractive cost
  • Available with either polypropylene or nylon hardware
  • High flow rates, low pressure drops, long life, and low extractables
  • Manufactured under strict control with batch number identification, giving full traceability on all components
  • Materials USP Class VI Plastics tested and meet US FDA Title 21 requirements
  • Full product validation guide available

Related Products

SupaPore NP

SupaPore NP Microfiltration cartridges use a pleated high surface area Nylon 66 membrane that has been designed for use in a wide range of liquid processing applications. The naturally hydrophilic Nyl...

High Flow Tetpor II

HIGH FLOW TETPOR II gas sterilisation filters have been developed to benefit from technological advances within the manufacture of PTFE membranes. This new generation of filter sets the standard with ...

Bio-X

HIGH FLOW BIO-X combines proven depth filter technology and a pleated construction to provide retention down to 0.01 micron in gas. Flow rates are typically 2-3 times that of membrane filters, making ...

Propor LR

PROPOR LR filters have been specifically designed for high flow and effective removal of Ralstonia pickettii and other diminutive organisms. A number of studies have concluded that not all microorgani...
Let’s talk

Our team is ready to discuss how we can find a performance solution for you.

Contact Us