Skip to content

Technical Specifications

Dimensions

  • Outside diameter: 68.5mm
  • Typical surface area: 0.22m² per 10” filter

Sterilisation and Sanitisation*2

  • Steam or Autoclave: 121°C for 15 mins (40 cycles)
  • Hot Water: 90°C for 30 mins (0.2 bar ?p max)

*2 Applies to single open end cartridges only. For all steaming and hot water applications, the Reinforced Polypropylene End Cap option must be used.

Maximum Operating Conditions

  • Temperature: 80ºC
  • Recommended Maximum Differential Pressure:
    • Forward Flow: 4.0 Bar @ 20ºC
    • Reverse Flow: 3.5 Bar @ 20ºC
  • Recommended change-out differential pressure: 2.5 Bar

Standard Materials of Construction

  • Filter Media: Borosilicate Glass Microfibre and Nanoalumina
  • Media support: Polypropylene
  • End Caps: Polypropylene
  • Cage/Core: Polypropylene

Product validation guide available on request. All SupaPore Nanofibre cartridges are manufactured under strict control with batch number identification, giving full traceability on all components.

Features and Benefits

  • Relatively open porous structure offering high flow rates and long in-process life times
  • High Zeta potential for effective removal of ultrafine contaminants
  • Enormous internal surface area providing high capacity for contaminant removal
  • Media tested to ensure suitability for critical processes including pharmaceutical applications and potable water
  • Product Validation Guide available
  • All individual packing bags are anti-static
  • Not recommended for dialysis applications

Related Products

SupaPore VPWS

Within the beverage industry, it is important that products are microbiologically stabilised prior to packaging to prolong shelf life, and this is achieved without affecting the nature of the product....

Propor ME

PROPOR ME is an advanced filter cartridge that provides a cost-effective means of particulate removal and microbial reduction in wine applications. PROPOR ME filter cartridges are available in a range...

SupaPore TTE

Dimensions Outside Diameter: 70mm Typical Surface Area: 0.63m² (Per 10”) Length: See ordering guide Maximum Operating Conditions Temperature: 150ºC Sterilisation and Sanitisation Steam or Aut...

Propor SG

PROPOR SG sterilising grade filters feature a patented, microbially retentive polyethersulphone membrane for fast, reliable, and cost-effective sterile filtration of pharmaceutical fluids. The asymmet...
Let’s talk

Our team is ready to discuss how we can find a performance solution for you.

Contact Us