Skip to content

Technical Specifications

Materials of Construction

  • Filtration Membrane: Polyethersulphone
  • Upstream Support: Polyester
  • Downstream Support: Polyester

Filter Cartridges

  • Inner Support Core: Polypropylene
  • Outer Protection Cage: Polypropylene
  • End Caps: Nylon
  • End Caps Insert: 316L Stainless Steel
  • Standard o-rings/gaskets: Silicone

MURUS Disposable Filter Capsules

  • Core: Polypropylene
  • Sleeve: Polypropylene
  • Standard o-rings/gaskets: Silicone
  • Capsule Body: Polypropylene
  • Capsules Vent Seals: Silicone

DEMICAP Filter Capsules

  • Core: Polypropylene
  • Sleeve: Polypropylene
  • End Caps: Nylon
  • Capsule Body: Nylon
  • Capsules Vent Seals: Silicone
  • Filling Bell: Polycarbonate

Syringe Filters

  • Body: Polypropylene

Recommended Operating Conditions

  • Filter Cartridges: Up to 70 °C (158 °F) continuous operating temperature and higher short-term temperatures during CIP to the following limits.
  • MURUS Disposable Filter Capsules: Up to 25 °C (77 °F) @ 5.5 barg (79.7 psig); Up to 60 °C (140 °F) @ 2.8 barg (40.6 psig)
  • DEMICAP Filter Capsules: Up to 40 °C (104 °F) at line pressures up to 5.0 barg (72 psig).

Parker Hannifin certify that this product complies with the European Council Pressure Equipment Directive (PED) 97/23/ EC Article 3, Paragraph 3 – Sound Engineering Practice (SEP). This product is intended for use with Group 1 & 2 Dangerous and Harmless Liquids and Group 2 Harmless Gases at the operating conditions stated in this document: In compliance with PED Article 3, Paragraph 3, SEP, this product does not bear the CE mark.

Effective Filtration Area (EFA)

  • 10¨ (250 mm): 0.55 m² (5.92 ft²)
  • K Size: 0.26 m² (2.79 ft²)
  • A Size: 0.20 m² (2.15 ft²)
  • B Size: 0.10 m² (1.07 ft²)
  • E Size: 0.05 m² (0.53 ft²)
  • Syringe ø50 mm: 14.50 cm² (2.25 in²)

Sterilization

PROPOR SG filter cartridges can be sanitised with hot water at up to 90 °C (194 °F) and are compatible with a wide range of chemicals. For detailed operational procedures and advice on cleaning and sterilisation, please contact the Technical Support Group through your usual Parker domnick hunter contact.

Food and Biological Safety

Materials conform to the relevant requirements of 21CFR Part 177 and current USP Plastics Class VI – 121 °C and ISO10993 equivalents.

Quality Standards

Pharmaceutical grade products are manufactured in accordance with cGMP, 100% flushed with pharmaceutical purified water and integrity tested prior to despatch. A sample of each lot is tested to demonstrate conformity to validated claims.

Gamma-Irradiation

PROPOR SG MURUS & DEMICAP disposable filters can be gamma-irradiated up to a maximum dosage of 40 kGy.

Features and Benefits

  • Up to 3.5 times higher flow rates than competitive sterilising grade filters
  • Fully validated and integrity testable membrane for assurance of sterility
  • Low binding for minimal product loss
  • MURUS and DEMICAP’s can be gamma-irradiated and autoclaved

Related Products

Tetpor Air

TETPOR AIR sterilization filter cartridges offer exceptional filtration performance while providing the highest levels of biosecurity throughout the process industry. Operating at ambient temperature ...

Bio-X Vent Autoclave

HIGH FLOW BIO-X combines proven depth filter technology and a pleated construction to provide retention down to 0.01 micron in gas. Flow rates typically 2-3 times that of membrane filters make HIGH FL...

Bio-X

HIGH FLOW BIO-X combines proven depth filter technology and a pleated construction to provide retention down to 0.01 micron in gas. Flow rates are typically 2-3 times that of membrane filters, making ...

High Flow Tetpor HT

HIGH FLOW TETPOR H.T. gas sterilisation filter cartridges provide unrivalled performance in process industry applications where continuous cartridge operation of up to 100 °C (212 °F) is a requireme...
Let’s talk

Our team is ready to discuss how we can find a performance solution for you.

Contact Us