Skip to content

Technical Specifications

Dimensions

  • Outside Diameter: 68.5mm
  • Typical Surface Area: 0.65m² (Per 10”)
  • Length: See ordering guide

Sterilisation and Sanitisation*1

  • Steam or Autoclave:
    • 121°C for 60 mins (240 cycles)
    • 135°C for 30 mins (25 cycles)
  • Hot Water: 90°C for 30 mins (0.2 bar ?p max)

*1 Applies to single open end cartridges only. For all steaming and hot water applications, the Reinforced end cap option must be used.

Maximum Operating Conditions

  • Temperature: 80ºC
  • Recommended Maximum Differential Pressure:
    • Forward Flow: 4.0 Bar @ 20ºC
    • Reverse Flow: 3.5 Bar @ 20ºC

Materials of Construction

  • Filter Media: Polyethersulphone (PES)
  • Pre Filter: Polyethersulphone
  • Media Support: Polypropylene
  • End Caps: Polypropylene
  • Cage/Core: Polypropylene

Bacterial Challenge

  • 16VPBA02: LRV >11 (Brevundimonas diminuta

Features and Benefits

  • Naturally hydrophilic PES membrane
  • Built-in integral pre-filter layer
  • 5 to 40” length options with a range of common end caps
  • Comprehensive validation guide available
  • Low binding for minimal active ingredient loss
  • Excellent chemical compatibility
  • Can be regenerated for extended service life
  • Can be repeatedly integrity tested
  • Range of removal ratings and validated for consistent and reliable performance

Note: Steaming, autoclaving, and hot water sanitisation must use the Reinforced PP end-cap option

1See product guides for further details stating test method and rated efficiencies

Related Products

Prepor NG

Parker domnick hunter’s continued focus on process optimization and control has led to the development of a new range of prefilters for the clarification and pre-stabilization stages of wine process...

SupaPore VPWS

Within the beverage industry, it is important that products are microbiologically stabilised prior to packaging to prolong shelf life, and this is achieved without affecting the nature of the product....

SupaPore TTE

Dimensions Outside Diameter: 70mm Typical Surface Area: 0.63m² (Per 10”) Length: See ordering guide Maximum Operating Conditions Temperature: 150ºC Sterilisation and Sanitisation Steam or Aut...

Tetpor Liquid (Membrane)

TETPOR LIQUID filters are particularly suitable for sterilisation and particulate removal from aggressive chemicals (including acids, bases, and solvents) within a wide range of critical processing in...
Let’s talk

Our team is ready to discuss how we can find a performance solution for you.

Contact Us