Technical Specifications

Materials of Construction

  • Filtration Membrane: Polyethersulphone
  • Upstream Support: Polyester
  • Downstream Support: Polyester
  • Inner Support Core: Polypropylene
  • Outer Protection Cage: Polypropylene
  • End Caps: Nylon
  • End Cap Insert (if applicable): 316L Stainless Steel
  • Standard o-rings/gaskets: Silicone / EPDM
  • Capsule Body: Nylon
  • Capsule Vent Seals: Silicone

Food and Biological Safety

Materials conform to the relevant requirements of 21CFR Part 177, EC1935 / 2004 and current USP Plastics Class VI – 121 °C and ISO10993 equivalents.

Recommended Operating Conditions

Up to 70 °C (158 °F) continuous operating temperature and higher short-term temperatures during CIP to the following limits:

Capsules may be operated up to a temperature of 40 °C (104 °F) at line pressures up to 5.0 barg (72.51 psig) for liquids and 4.0 barg (58.01 psig) in air / gas.

Effective Filtration Area (EFA)

10” (250 mm): 0.6 m² (6.45 ft²)

Cleaning and Sterilisation

BEVPOR PS cartridges can be repeatedly steam sterilised in situ or autoclaved at up to 130 °C (266 °F). They can be sanitised with hot water at up to 90 °C (194 °F) and are compatible with a wide range of chemicals. Capsules can be repeatedly autoclaved up to 130 °C (266 °F).

For detailed operational procedures and advice on cleaning and sterilisation, please contact the Technical Support Group through your usual Parker domnick hunter contact.

Retention Characteristics

The retention characteristics of BEVPOR PS have been determined by a combination of controlled laboratory tests and in-use monitoring for a number of organisms. Bacterial challenge testing is carried out to methods specified in ASTM F838-05.

Integrity Test Data

All filters are flushed with pharmaceutical grade purified water prior to despatch. They are integrity tested to the following limits:

Recommended Rinse Volume

Prior to use – 5 litres per 10” (250 mm) filter cartridge.

Features and Benefits

  • Removal ratings from 0.2 to 1.2 micron
  • Repeatedly integrity testable
  • Cartridge can be regenerated and sanitised for extended service life
  • Low adsorption of protein, colour, and flavour components
  • Asymmetrical pore structure provides high capacity contaminant loading

Related Products

Propor LR

PROPOR LR filters have been specifically designed for high flow and effective removal of Ralstonia pickettii and other diminutive organisms. A number of studies have concluded that not all microorgani...

SupaPore NP

SupaPore NP Microfiltration cartridges use a pleated high surface area Nylon 66 membrane that has been designed for use in a wide range of liquid processing applications. The naturally hydrophilic Nyl...

Tetpor Air

TETPOR AIR sterilization filter cartridges offer exceptional filtration performance while providing the highest levels of biosecurity throughout the process industry. Operating at ambient temperature ...

Bio-X Vent Autoclave

HIGH FLOW BIO-X combines proven depth filter technology and a pleated construction to provide retention down to 0.01 micron in gas. Flow rates typically 2-3 times that of membrane filters make HIGH FL...
Let’s talk

Our team is ready to discuss how we can find a performance solution for you.

Contact Us